Provided by: dlt-daemon_2.18.10-12_amd64 

NAME
dlt_gateway.conf - DLT configuration file for gateway
DESCRIPTION
The configuration file dlt_gateway.conf allows to configure the different runtime behaviour of gateway in
Multinode feature.
The configuration file is written in an INI file format and contains information about different
connected passive nodes.
If Multinode feature is enabled, dlt-daemon loads by default the configuration file
/etc/dlt_gateway.conf.
An alternative configuration file can be loaded by changing GatewayConfigFile in dlt.conf(5).
GENERAL SECTION
Interval
Time interval for reconnection to passive Node in second.
Default: 1
PASSIVENODE SECTION
Each passive node’s connection parameters are specified in a unique numbered separate section
([PassiveNode{1,2, ...N}]).
Example: [PassiveNode1]
IPaddress
Because TCP is the only supported communication channel,
the IPaddress and Port of the Passive DLT Daemon has to be specified.
IP Address of passive node. Mandatory
Port
TCP port. Default 3490 is used if no port is specified.
Default: 3490
EcuID
ECU identifier of passive node. Mandatory.
Connect
With the Connect property it is possible to specify when the Gateway DLT Daemon shall connect to the
passive node.
Default: OnStartUp
The following values are allowed:
OnStartup The Gateway DLT Daemon tries to connect to the Passive DLT Daemon
immediately after the Gateway DLT Daemon is started.
OnDemand The Gateway DLT Daemon tries to connect to the Passive DLT Daemon
when it receives a connection request.
Timeout
Stop connecting to passive node, if not successful after 10 retries.
After of retries, the connection to passive Node is marked as DISABLED.
It means there is no any retry anymore.
Set to 0 for endless retry.
Default: 10
SendControl
Send following control messages after connection is established. Optional.
Default: disabled
Supported Control messages:
DLT_SERVICE_ID_GET_LOG_INFO 0x03
DLT_SERVICE_ID_GET_DEFAULT_LOG_LEVEL 0x04
DLT_SERVICE_ID_GET_SOFTWARE_VERSION 0x13
SendSerialHeader
Send Serial Header with control messages. Value in dlt.conf(5) is used as default if not specified.
Default: disabled
SendPeriodicControl
Send following control messages periodically.
Default: disabled
Format:
control:interval[in seconds]
AUTHOR
Thanh Bui Nguyen Quoc (thanh.buinguyenquoc (at) vn (dot) bosch (dot) vn)
COPYRIGHT
Copyright (C) 2020 Advanced Driver Information Technology, Bosch and DENSO. License MPL-2.0: Mozilla
Public License version 2.0 http://mozilla.org/MPL/2.0/.
BUGS
See Github issue: https://github.com/COVESA/dlt-daemon/issues
SEE ALSO
dlt.conf(5), dlt-daemon(1)